Capabilities of the test rigs
- Complete Measurements of Turbo Chargers (Compressor and Turbine), Mechanical Chargers and Pressure Wave Superchargers
- Temperature Variation T1 0°C - 50°C, T3 Turbine 200°C - 1050°C
- Throughput Range 0,005 - 0,60 kg/s
- PiTU at 800 °C 4.0 below 0.05 kg/s; 5.0 above 0.05 kg/s
- Low Pressure Restriction Variations before Compressor and after Turbine
- Variations of Oil Temperature and Oil Pressure
- Measurements with Engine and Vehicle Components (Air Filter, Exhaust Pipes, Mufflers, Charge Air Cooler, …)
- Oil Consumption and Blow-By Measurements of Turbo Chargers
- Acoustical- and Vibration Measurements of Chargers and Peripheral Parts
- Durability Tests (Actuation Forces, Temperature Profiles)